081318501594 BOD METER AL606 & AL612 BOD Measurement System with Direct sample selection & Interface/ Biochemical Oxygen Demand ( BOD) / BOD Meter/ Lovibond Tintometer.ANA: 021-96835260 HP: 081318501594 email suksesmakmur65@ yahoo.com[18 Jan. 2012, 19:48:30]
081318501594 AL606 & AL612 BOD Measurement System with Direct sample selection & Interface/ Biochemical Oxygen Demand ( BOD) / BOD Meter.ANA: 021-96835260 HP: 081318501594 email suksesmakmur65@ yahoo.com
Highlights
Direct sample selection
Accurate and direct display of BOD values in mg/ l
User-friendly handling
User-selectable measuring period from 1 to 28 days ( BOD5, BOD7, OECD⦠)
Storage of all values
Measuring ranges from 0-40 mg/ l to 0-4000 mg/ l BOD, sample volume related
Auto start function after temperature equalisation
Mercury-free, environmentally-friendly
Inductive stirring system with automatic re-centering of stirring rods
Interface RS 232
Description
AL606 & AL612
The AQUALYTIC sensor system AL606 is a 6 sample system that allows precise measurements of BOD based on the manometric principle. Manometric respirometers relate oxygen uptake to the change in pressure caused by oxygen consumption while maintaining a constant volume. Thanks to the modern integral pressure sensors, it is no longer necessary to use mercury for pressure measurements.
Technical data
- Meas. principle Manometric; mercury-free; electronic pressure sensor
- Ranges [ mg/ l O2] 0 - 40, 0 - 80, 0 - 200, 0 - 400, 0 - 800, 0 - 2000, 0 - 4000 mg/ l
- Accuracy* 0.5 % full scale at 20° C
- Applications BOD5, BOD7, OECD 301 F ...
- Result display BOD [ mg/ l] ; 4 - digits ; 7 - segment LED
- Measurement parameter display BOD-range, volume, duration, time of measurement
- Measurement period User-selectable, between 1 and 28 days
- Auto result storage Up to 28 results, depending on measurement period
- Storage interval â hourly ( 1 day) â every 2 hours ( 2 days) â daily ( 3-28 days)
- Automatic start function â After temperature equalisation of samples â Can be switched off
- Power supply 3 alkaline-manganese batteries ( â Babyâ cells/ size â Câ )
- Battery life 1 year ( normal use as BOD5 meter â max. one reading a day) ; early warning before battery fails
- Interface RS 232 for printer or PC connection
- Clock Real-time clock
- Protection class IP 54 ( sensor head)
- Dimensions ( L x W x H) 375 x 195 x 230 mm including stirring unit
- Weight 3850 g, unit with bottles 5750 g, complete with stirring unit
- Housing ABS
- CE-Conformity